User Tools

Site Tools


full_syntax

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision Both sides next revision
full_syntax [2019/10/10 13:50]
marijn.nijenhuis [5. Optional]
full_syntax [2020/06/05 13:37]
marijn.nijenhuis [5. Optional]
Line 155: Line 155:
 | ''transfer'' | ''true'' | Calculation of state-space equations. Requires specification of at least one input and one output, by means of ''nprops(i).transfer_in'' and ''nprops(i).transfer_out''. Cannot be used with applied forces, applied moments, prescribed displacements, and buckling load multipliers. | | ''transfer'' | ''true'' | Calculation of state-space equations. Requires specification of at least one input and one output, by means of ''nprops(i).transfer_in'' and ''nprops(i).transfer_out''. Cannot be used with applied forces, applied moments, prescribed displacements, and buckling load multipliers. |
 | ::: | 1×2 cell | Calculation of state-space equations that include relative damping for all modes of the system. (This value only affects the output in ''out.statespace''; the eigenfrequency output in ''out.freq'' and Spavisual remain undamped.) For example: ''opt.transfer = {true 0.01}'' calculates state-space equations with relative damping 0.01. | | ::: | 1×2 cell | Calculation of state-space equations that include relative damping for all modes of the system. (This value only affects the output in ''out.statespace''; the eigenfrequency output in ''out.freq'' and Spavisual remain undamped.) For example: ''opt.transfer = {true 0.01}'' calculates state-space equations with relative damping 0.01. |
 +|''customvis''| ''{'modeshape','maximum 20'}'' | The maximum number of mode shapes, in this case 20, that are shown in the Spavisual window. If omitted, the default value of 10 is used. |
 ===== Output Arguments ===== ===== Output Arguments =====
  
full_syntax.txt · Last modified: 2023/11/09 22:27 by marijn.nijenhuis